Highway Tanks and TC Portable Tanks - Registered per Standard CSA B620 - Details

Registration

  • Registration Number
    25-0608
  • Registration Type
    Container Facility - Highway Tanks and TC Portable Tanks
  • Issue Date
    4/13/2022
  • Expiry Date
    7/1/2025

Site Details

  • Company Name
    Truck Zone Inc.
  • Facility Address
    5205 - 65th Street, Lloydminster, AB, Canada
  • Phone Number
  • Email

Additional Information

  • Registered Marks
    None
  • Other registrations held

Facility Functions

Piping modification

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None

Piping manufacture

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 406
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude

Limitations: None

Wet fluorescent magnetic particle inspection

Specifications:
TC 331

Limitations: None

External visual inspection

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None

Leak test

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude

Limitations: None

Upper coupler inspection

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None

Linings and coatings qualify

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude

Limitations: None

Piping repair

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations:
Mobile units are permitted for this function.

Internal visual Inspection

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude

Limitations: None

Mobile service

Specifications:
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None

Thickness test

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None

Tank assembly

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 406
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude

Limitations: None

Pneumatic pressure test

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None

Tank repair

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations:
Mobile units are permitted for this function.
Mobile units are permitted for this function.

Tank modification

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None

Hydrostatic pressure test

Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338

Limitations: None