Highway Tanks and TC Portable Tanks - Registered per Standard CSA B620 - Details
Registration
- Registration Number
25-0608 - Registration Type
Container Facility - Highway Tanks and TC Portable Tanks - Issue Date
4/13/2022 - Expiry Date
7/1/2025
Site Details
- Company Name
Truck Zone Inc. - Facility Address
5205 - 65th Street, Lloydminster, AB, Canada - Phone Number
- Email
Additional Information
-
Registered Marks
None
-
Other registrations held
Facility Functions
Piping modification
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None
Piping manufacture
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 406
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
Limitations:
None
Wet fluorescent magnetic particle inspection
Specifications:
TC 331
Limitations:
None
External visual inspection
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None
Leak test
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
Limitations:
None
Upper coupler inspection
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None
Linings and coatings qualify
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
Limitations:
None
Piping repair
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
Mobile units are permitted for this function.
Internal visual Inspection
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
Limitations:
None
Mobile service
Specifications:
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None
Thickness test
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None
Tank assembly
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 406
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
Limitations:
None
Pneumatic pressure test
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None
Tank repair
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
Mobile units are permitted for this function.
Mobile units are permitted for this function.
Tank modification
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None
Hydrostatic pressure test
Specifications:
TC 407 (non vacuum, MAWP ≤ 240 kPa)
TC 412 (non vacuum, MAWP ≤ 103 kPa)
TC 307 (non vacuum, MAWP ≤ 345 kPa)
TC 312 (MAWP ≤ 103 kPa)
TC 406
TC 312 (MAWP > 103 kPa)
TC 350 (MAWP ≤ 103 kPa)
TC 306
TC 307 (vacuum loaded OR MAWP > 345 kPa)
TC 331
TC 407 (vacuum loaded OR MAWP > 240 kPa)
TC 412 (vacuum loaded, MAWP > 103 kPa)
TC 406 Crude
TC 306 Crude
TC 350 Crude
TC 338
Limitations:
None